HTC Gateway - How to Combine 2 or more Projects

HTC Gateway - How to Combine 2 or more Projects



1) Verify or Add all of the sensors that you want in your combined project into the project are are going to keep.

2) Make sure that the Pour Date & Time is correct on all of the sensors.

3) With  the project open that you are going to keep, click on Sensors, Logging, Restart All  --OR-- single click on the sensors that you are moving to the combined project and click on Sensors, Logging, Restart
- This process will ask if you want to move the data stream away from the other project(s) that are logging temperature data for the sensors.  Please click "Yes" to these question(s).

This is an example, project D P is the project we would like to keep and combine the sensors and data from project D



1) This is project D P with Sensors 947, 105, and 104. We verified the Pour Date & Time and we have all of the sensors that we want in the final combined project: D P:


2) Single click on the sensors that you are moving to this project and click on Sensors, Logging, Restart  --OR-- Click on Sensors, Logging, Restart All



You will be asked if you would like to move the data stream for the sensor that are currently logging on other projects.  Please click "Yes", so that HardTrack will turn off logging on for the sensors in the other projects and move the data stream to the combined project that you are going to keep:




    • Related Articles

    • HTC Gateway - How to Scan for Wireless Sensors

      Click on Sensors, Scan for Wireless Sensors, then select the range of sensors that you within the field of interrogation. If you are not sure and/or you would like the HTC Gateway to try as hard as it can to locate the Wireless Sensors, select the ...
    • Shipping the HTC II - Ground Only!

      When you ship the HTC II, due to DOT regulations, they must be shipped ground only with the following labels.   Each carton must include all (3) of these labels: a label stating that it is forbidden for transport aboard aircraft and vessels. a UN ...
    • Installing the HardTrack Cloud Gateway - Stationary Gateway

      The HardTrack Cloud Gateway - Stationary device (HTC Gateway) is intended for use in a permanent or semi-permanent location, such as a precast concrete facility, precast concrete yard, a large civil construction project, or a high rise building ...
    • HTC Gateway - How to set up a new Concrete Pour - Best Practices

      Starting with version 5.1._02.33 of HardTrack Desktop, this is the best procedure to follow to set up a new HardTrack Project and Start the Sensors/Tags Logging. On your PC using HardTrack Desktop, start by adding Known Sensors to your new HardTrack ...
    • Installing the HardTrack Cloud Gateway - Remote Reader

      The HardTrack Cloud Gateway (HTC Gateway) Remote Reader is intended for use in a permanent or semi-permanent location, such as a precast concrete facility, precast concrete yard, a large civil construction project, or a high rise building ...